Product description
The JSBLFLP is a fully drainable compact back pressure regulator designed and built specifically for hygienic, ASME BPE low flow and low pressure gas and liquid applications.Applications
- It's been designed specifically to eliminate all threaded connections and contaminant traps below the diaphragm.
- It is completely drainable (an industry first in compact hygienic regulator design), and compatible with CIP and SIP
practices. See drainability guideline on page 6. - The simple trim design facilitates quick trim change out and
cleaning without valve removal or complete disassembly.
Back Pressure Reducing Valve JSBLFLP
Size
- 3/8″ (DN10), 1/2″ (DN15), 3/4″ (DN20)
End Connections
- Tri-Clamp, Tube Weld End to ASME BPE, DIN or ISO dimensions as standard
Cv & Flow Characteristics
• Cv 0.05 (0,04); for relief valve sizing is 0.15(0,13)
• Cv 0.15(0,13); for relief valve sizing is 0.25(0,21)
• Cv 0.25(0,21); for relief valve sizing is 0.35(0,30)
• Cv 0.35(0,30); for relief valve sizing is 0.45(0,39)
• Cv 0.15(0,13); for relief valve sizing is 0.25(0,21)
• Cv 0.25(0,21); for relief valve sizing is 0.35(0,30)
• Cv 0.35(0,30); for relief valve sizing is 0.45(0,39)
Maximum Inlet Pressure
• Weld-End, or Tri-Clamp Connections: 150 psig (10,5 barg)
• NPT Connections: 450 psig (31 barg)
• NPT Connections: 450 psig (31 barg)
Spring Ranges
- 2 – 15 psi (0,14 – 1 bar); 10-25 psi
Wetted Material
- ASME SA479 316L (UNS 31603) is standard. EN 10272:2000 GR 1.4435, AL-6XN®, Hastelloy C-22 and others are optional
Surface Finish
- Internal wetted components: ASME BPE SF5, 20Ra μin, (0,5 Ra μm) electropolished
- External: 40 Ra μin (1,0 Ra μm) electropolished
- Other finishes optional
Diaphragm Materials
- PTFE-based Jorlon; FDA, USP Class VI
Soft Seat Materials for ANSI Class VI Shut-Off
• TFM to +450°F (232°C) FDA, USP Class VI
• PEEK to +350°F (177°C) FDA, USP Class VI
• PEEK to +350°F (177°C) FDA, USP Class VI
Optional Cleaning Specifications
• Clean for Oil-Free
• O2 Cleaning complying with ASTM G93-03 2011 and CGA G-4.1-2009
• O2 Cleaning complying with ASTM G93-03 2011 and CGA G-4.1-2009
Options
- Panel Mounting
- Air Augment
- Inlet-Outlet Gauge
Features and Benefits
- Fully drainable with no threaded connections, or contaminant traps below the diaphragm
- In-line removable trim significantly reduces maintenance time
- Barstock construction guarantees material integrity and surface finish
- Minimized internal volume
- Proprietary Jorlon diaphragm material provides exceptionally long life and CIP/SIP capability, and FDA and USP Class VI compliance and is warrantied for life.
- Soft seat material for ANSI Class VI shutoff