ViscoTec Hygienic Pharma Dispenser VPHD
Dosing volume (ml/ rev) = recommended min. dosing volume | Max. volume flow (ml/min) | Max. dosing pressure (bar) | Max. inlet pressure (bar) | Dosing accuracy (%) | Repeatability (%) | Operating temperature (°C) | Material temperature (°C) | Max. rotation speed (U/min) | Weight without drive (kg) | Volume pump housing (ml) |
---|---|---|---|---|---|---|---|---|---|---|
~ 0.17 (1) Depends on material |
24 (2) Depends on viscosity and primary pressure |
20 (1) |
5 (1) |
± 1 (3) Volumetric dosing as absolute deviation in relation to one dispenser revolution. Depends on the viscosity of the material |
> 99 (1) |
10 - 40 |
10 - 40 (1) |
140 (4) Higher speed causes increased wear |
~ 1.8 |
~ 21 |
Dosing volume (ml/ rev) = recommended min. dosing volume | Max. volume flow (ml/min) | Max. dosing pressure (bar) | Max. inlet pressure (bar) | Dosing accuracy (%) | Repeatability (%) | Operating temperature (°C) | Material temperature (°C) | Max. rotation speed (U/min) | Weight without drive (kg) | Volume pump housing (ml) |
---|---|---|---|---|---|---|---|---|---|---|
~ 0.35 (1) Depends on material |
49 (2) Depends on viscosity and primary pressure |
20 (1) |
5 (1) |
± 1 (3) Volumetric dosing as absolute deviation in relation to one dispenser revolution. Depends on the viscosity of the material |
> 99 (1) |
10 - 40 |
10 - 40 (1) |
140 (4) Higher speed causes increased wear |
~ 1.8 |
~ 21 |
Dosing volume (ml/ rev) = recommended min. dosing volume | Max. volume flow (ml/min) | Max. dosing pressure (bar) | Max. inlet pressure (bar) | Dosing accuracy (%) | Repeatability (%) | Operating temperature (°C) | Material temperature (°C) | Max. rotation speed (U/min) | Weight without drive (kg) | Volume pump housing (ml) |
---|---|---|---|---|---|---|---|---|---|---|
~ 1.7 (1) Depends on material |
238 (2) Depends on viscosity and primary pressure |
20 (1) |
5 (1) |
± 1 (3) Volumetric dosing as absolute deviation in relation to one dispenser revolution. Depends on the viscosity of the material |
> 99 (1) |
10 - 40 |
10 - 40 (1) |
140 (4) Higher speed causes increased wear |
~ 2.5 |
~ 33 |
Dosing volume (ml/ rev) = recommended min. dosing volume | Max. volume flow (ml/min) | Max. dosing pressure (bar) | Max. inlet pressure (bar) | Dosing accuracy (%) | Repeatability (%) | Operating temperature (°C) | Material temperature (°C) | Max. rotation speed (U/min) | Weight without drive (kg) | Volume pump housing (ml) |
---|---|---|---|---|---|---|---|---|---|---|
~ 5.1 (1) Depends on material |
714 (2) Depends on viscosity and primary pressure |
15 (1) |
5 (1) |
± 1 (3) Volumetric dosing as absolute deviation in relation to one dispenser revolution. Depends on the viscosity of the material |
> 99 (1) |
10 - 40 |
10 - 40 (1) |
140 (4) Higher speed causes increased wear |
~ 2.5 |
~ 33 |
ViscoTec Hygienic Pharma Dispenser VPHD
VISCOTEC PHARMA DISPENSER VPHD HYGIENIC DESIGN
The pump system is ideal for dosing various fluids in the ml range of dosing volume: 0.1 ml/rev to 5.1 ml/rev and Volume flow: 0.2 ml/min to 800 ml/min. The high flexibility in the programming allows a very good adjustment for each dosing applications, filling highly viscous products. The dosing operation is very simple to adjust by changing the dosing speed and the possibility to set up a suck back after dosing to get a clean cut of the thread and through the easy combination with different dosing nozzles, the Pharma Dispenser could be individually tailored to any dosing application. With these pumps it is possible to dispense small amounts (starting from 0.5 ml) very accurately and with a highly repeatable level. Also by using the pump within a small production batch for several hours the pumps run reliably and the dosing is reproducible. The cleaning of the system is very easy and can be done without any residues within the pump. Thanks to it's construction, an easy flushing is sufficient to clean the pump. Because of the compact design of the dosing unit (pump and drive) it is possible to get the dosing needles very close together.
Your advantages:
- Compact & hygienic design for food and cosmetic applications
- Volumetric dosing, regardless of viscosity
- For low to high viscosity materials
- Particularly suitable for abrasive, filled or shear sensitive materials
- Continuous dosing, pulsation free
- Precise filling with high repeatability
- Linear relation between dosing volume and rotation speed
- Programmable suck-back prevents dripping or stringing of product
- Easy cleaning and maintenance due to quick assembly and disassembly options
- Optional flushing connection for automated cleaning
- Easy integration in automated processes
- Autoclavability of wetted components
Want to Learn More?
For product inquiries or other concerns, we are happy to assist you. Simply share your question via our contact form, and we will get back to you promptly. Would you like to learn more about Aseptconn’s complete product portfolio? Find the right products for pharmaceuticals, biotech, cosmetics, and more in our product portfolio, and find kits for Skids and machines, Tri-Clamp connections, hoses and much more.